Home Subscription Services
 
   

 
World Journal of Orthodontics
WJO Home Page
About the Editor
Editorial Board
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTube
Quintessence Publishing: Journals: ORTHODONTICS
ORTHODONTICS
The Art and Practice of Dentofacial Enhancement

Formerly World Journal of Orthodontics

Edited by
Rafi Romano, DMD, MSc (Editor-in-Chief)

ISSN 2160-2999 (print) / ISSN 2160-3006 (online)

Visit the ORTHODONTICS: The Art and Practice of Dentofacial Enhancement Facebook page

Publication:
Winter 2010
Volume 11 , Issue 4

Back
Share Abstract:

Effect Of Fluoride Solutions On The Structure And Hardness Of Plastic Brackets

Christina Tziafa, DDS/Spiros Zinelis, PhD/Margarita Makou, DDS, MS/Theodore Eliades, DDS, MS, Dr Med, PhD/George Eliades, DDS

Pages: 398–403
PMID: 21491008

Aim: To investigate the surface morphology, structure, molecular and elemental composition, and hardness of plastic brackets exposed to fluoride solutions. Methods: Two types of plastic brackets (Silkon Plus and SpiritMB) were exposed to three fluoride solutions 10 times for 1 minute each and then subjected to attenuated total relectance-Fournier transform infrared (ATR-FTIR) spectroscopy, scanning electron microscopy (SEM), x-ray energy dispersive microanalysis (EDS), and Vickers hardness (HV) testing. Hardness data were analyzed via two-way ANOVA and Tukey tests at the .05 level of significance with brackets and fluoride solution as predictors. Results: ATR-FTIR spectroscopy showed that both bracket types consisted of polycarbonate. After treatment with acidulated phosphate fluoride, an increased contribution of –OH peaks at 3,200 cm–1(stretching [str]) and 1,640 cm–1 (a type of vibration [b]) was observed in both brackets. SEM revealed that the acidulated phosphate fluoride solution had a strong effect on the morphology and surface structure of the two brackets; a general deterioration with projections of the reinforcing fibers was observed. EDS showed evidence of aluminum, calcium, silicon, magnesium, and titanium, which could be attributed to the reinforcing glass fiber constituents. Hardness ranged in the order of 20 HV with no difference among the two bracket types and the three fluoride exposures. Conclusion: Repeated exposure of plastic brackets to fluoride solutions has a pronounced effect on their structure and morphology, but not their hardness. World J Orthod 2010;11:398–403.

Key words: plastic brackets, hardness, morphology, fluoride exposure, SEM

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files.
This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site
to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog