Home Subscription Services
 
   

 
World Journal of Orthodontics
WJO Home Page
About the Editor
Editorial Board
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: ORTHODONTICS
ORTHODONTICS
The Art and Practice of Dentofacial Enhancement

Formerly World Journal of Orthodontics

Edited by
Rafi Romano, DMD, MSc (Editor-in-Chief)

ISSN 2160-2999 (print) / ISSN 2160-3006 (online)

Visit the ORTHODONTICS: The Art and Practice of Dentofacial Enhancement Facebook page

Publication:
Winter 2008
Volume 9 , Issue 4

Back
Share Abstract:

Clinical application of a stereo-lithographic surgical guide for simple positioning of orthodontic mini-implants

Seong-Hun Kim, DMD, MSD/Ju-Man Kang, DDS/Bohm Choi, DDS, MSD/Gerald Nelson, DDS

Pages: 371382
PMID: 19146019

Aim: To describe a clinical application of a new surgical guide system that uses cone-beam computed tomography (CBCT) images, an implant-positioning program (SimPlant), and stereolithography to make a surgical guide for accurate placement of orthodontic mini-implants. Methods: A patient who was planning to have orthodontic mini-implant treatment on the posterior maxilla was recruited to assess the feasibility of using CBCT images in an implant-positioning guide program (SimPlant 9.02, Materilise, Leuven, Belgium). Acquisition slices for the posterior maxilla were 0.15 mm in panoramic mode of PSR 9000N model (Asahi Roentgen, Kyoto, Japan). The surgical guide for the mini-implant was fabricated from the transported CBCT data. Results: The completed surgical guide was easily placed intra-orally and permitted simple and rapid placement of the mini-implant. The site of the implant placement was accurate, while the vector varied slightly from the planned vector. Conclusion: A postplacement CBCT demonstrated accurate placement of the mini-implant on the left and a minor discrepancy between the simulated mini-implant position and clinical position on the right. Improvements in the CBCT resolution and laser-scanning technology are likely to eliminate any discrepancies. World J Orthod 2008;9:371382.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files.
This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site
to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog