Home Subscription Services
 
 
Loading
NEW
Sign Up to Receive Quintessence Updates by Email
 

 
World Journal of Orthodontics
WJO Home Page
About the Editor
Editorial Board
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTubeRSS
Quintessence Publishing: Journals: ORTHODONTICS
ORTHODONTICS
The Art and Practice of Dentofacial Enhancement

Formerly World Journal of Orthodontics

Edited by
Rafi Romano, DMD, MSc (Editor-in-Chief)

ISSN 2160-2999 (print) / ISSN 2160-3006 (online)

Visit the ORTHODONTICS: The Art and Practice of Dentofacial Enhancement Facebook page

Publication:
Fall 2008
Volume 9 , Issue 3

Back
Share Abstract:

Effect of high-intensity LED units at reduced curing time on in vitro bond strength of orthodontic brackets

Nathália B. Palomares/Julio Pedra e Cal-Neto, DDS, MS/Hélio Sampaio-Filho, DDS, MS, PhD/Marco Antônio de Oliveira Almeida, DDS, MS/José Augusto Mendes Miguel, DDS, MS, PhD

Pages: 203–208
PMID: 18834003

Aim: To compare the shear bond strength of stainless steel brackets obtained by 3 high-intensive light-emitting diode (LED) units with conventional halogen polymerization. Methods: A standard light-curing adhesive paste was used to bond brackets using different lamps and curing times. Eighty permanent bovine incisors were obtained and randomly divided into 4 groups. The first group was bonded using a high-output halogen lamp for 20 seconds, which served as a positive control. The other 3 groups were bonded with high-intensive LED curing devices for 10 seconds. After 30 minutes, a universal testing machine was used to apply an occlusal shear force directly to the enamel-bracket interface at a speed of 0.5 mm/minute. The groups were compared using Kruskal-Wallis test. Results: Mean results and standard deviations for the groups were: group 1 = 11.22 MPa (1.68), group 2 = 10.35 MPa (1.92), group 3 = 11.19 MPa (2.62), and group 4 = 11.82 MPa (2.09). No significant difference was observed in the bond strengths of the 4 groups evaluated (P = .176). Conclusions: Under the conditions of the present study, the high-intensity LED units with reduced light-curing time bonded brackets to etched tooth enamel as well as the halogen-based light-curing units. World J Orthod 2008;9:203–208.

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files.
This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site
to get your copy of Adobe Acrobat Reader.
  © 2013 Quintessence Publishing Co, Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog