Home Subscription Services
 
   

 
World Journal of Orthodontics
WJO Home Page
About the Editor
Editorial Board
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTube
Quintessence Publishing: Journals: ORTHODONTICS
ORTHODONTICS
The Art and Practice of Dentofacial Enhancement

Formerly World Journal of Orthodontics

Edited by
Rafi Romano, DMD, MSc (Editor-in-Chief)

ISSN 2160-2999 (print) / ISSN 2160-3006 (online)

Visit the ORTHODONTICS: The Art and Practice of Dentofacial Enhancement Facebook page

Publication:
Yearbook 2013
Volume 14 , Issue 1

Back
Share Abstract:

Miniscrew design and bone response: Defining a correlation

Karan Bhalla, BDS, MDS/Anmol S. Kalha, OSRE, BSc, BDS, MDS


DOI: 10.11607/ortho.759

Aim: This prospective clinical trial aims at correlating miniscrew implant (MSI) micro/macro architecture, the method of placement, and biologic markers in peri-MSI crevicular fluid (PMICF) as indicators of bone response. A comparative evaluation of surface morphology of the MSIs before placement and after retrieval defines a correlation between the architecture of the MSIs and the bone- implant contact ratio. Methods: Two types of MSIs (hybrid and cylindric) were placed in ten patients using a split-mouth technique with the aid of a restricted random number table. Each of the MSIs was placed in the intraradicular area between the second premolar and first molar in the attached gingiva, 4 mm from the cementoenamel junction. The MSIs were immediately loaded, and PMICF was collected on days 0, 7, 14, 21, 28, and 42 and evaluated using a standard laboratory protocol. Surface morphology before placement and after retrieval of the MSI was observed using scanning electron microscopy (SEM) at a magnification of 11, 40, and 1,000. Results: Alkaline phosphatase (ALP) and aspartate aminotransferase (AST) levels observed were lower in the hybrid MSI in comparison to the cylindric MSI. For both MSIs, ALP and AST levels showed a trend of significant increase at days 0, 7, and 14 and then a significant decrease on days 21, 28, and 42. Observations from SEM showed an oxide layer over the entire surface of the bone-expanding hybrid MSI; this layer was observed only at the tip of the cylindric MSI. Conclusions: Levels of both the diagnostic tissue destruction biologic markers ALP and AST are significantly higher in cylindric MSIs compared with hybrid MSIs, indicating a correlation to the type and method of placement of the MSI. The inflammatory markers show a definitive trend, with an elevation until day 14 and a decline after that, indicating an active inflammatory process until day 14 that could be correlated to tissue trauma. Observations from the SEM show a greater oxide layer formation in the hybrid MSI, which could imply a better bone-MSI contact ratio. ORTHODONTICS (CHIC) 2013;14:e10e21. doi: 10.11607/ortho.759

Key words: temporary anchorage devices, bone remodeling, biologic markers, surface morphology and architecture

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files.
This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site
to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog