Home Subscription Services
 
   

 
World Journal of Orthodontics
WJO Home Page
About the Editor
Editorial Board
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTube
Quintessence Publishing: Journals: ORTHODONTICS
ORTHODONTICS
The Art and Practice of Dentofacial Enhancement

Formerly World Journal of Orthodontics

Edited by
Rafi Romano, DMD, MSc (Editor-in-Chief)

ISSN 2160-2999 (print) / ISSN 2160-3006 (online)

Visit the ORTHODONTICS: The Art and Practice of Dentofacial Enhancement Facebook page

Publication:
Yearbook 2012
Volume 13 , Issue 1

Back
Share Abstract:

Mini-implant loosening: 3D analysis using the finite element method

Allahyar Geramy, DDS, MSc/Jean Marc Retrouvey, DMD, MSc/Reza Jelodar, DDS, MSc/Hasan Salehi, DDS, MSc


Aim: Mini-implants are a relatively new device for absolute anchorage control in orthodontics. Their failure due to loosening is a multifactorial problem. Improper positioning of mini-implants with different diameters is evaluated in this study via the finite element method. Methods: Twelve 3D finite element models of a mandibular posterior segment were designed and included the first molar, a mini-implant, the periodontal ligament, and spongy and cortical bone. They were similar except for the mini-implant position and diameter (1.3, 1.6, and 2.2 mm). A vertical force of 300 N was applied to the occlusal molar surface. The von Mises stress and energy produced by the applied occlusal forces were assessed in the mini-implant and bone. Results: The stress findings were between 15.284 and 359.77 MPa for the mini-implants based on their diameters and locations. The mini-implant energy findings were between 0.00084 and 0.258 mJ. These ranges for bone stress and energy changes were 17.611 and 129.45 MPa and 0.296 and 1.575 mJ, respectively. Conclusion: A decrease in the distance between the mini-implant and tooth root has a direct effect on different parameters to explain mini-implant loosening. ORTHODONTICS (CHIC) 2012;13:e51e57.

Key words: absolute anchorage, finite element method, mini-implant loosening

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files.
This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site
to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog