Home Subscription Services
 
 
Loading
NEW
Sign Up to Receive Quintessence Updates by Email
 

 
World Journal of Orthodontics
WJO Home Page
About the Editor
Editorial Board
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTubeRSS
Quintessence Publishing: Journals: ORTHODONTICS
ORTHODONTICS
The Art and Practice of Dentofacial Enhancement

Formerly World Journal of Orthodontics

Edited by
Rafi Romano, DMD, MSc (Editor-in-Chief)

ISSN 2160-2999 (print) / ISSN 2160-3006 (online)

Visit the ORTHODONTICS: The Art and Practice of Dentofacial Enhancement Facebook page

Publication:
Yearbook 2012
Volume 13 , Issue 1

Back
Share Abstract:

Mini-implant loosening: 3D analysis using the finite element method

Allahyar Geramy, DDS, MSc/Jean Marc Retrouvey, DMD, MSc/Reza Jelodar, DDS, MSc/Hasan Salehi, DDS, MSc


Aim: Mini-implants are a relatively new device for absolute anchorage control in orthodontics. Their failure due to loosening is a multifactorial problem. Improper positioning of mini-implants with different diameters is evaluated in this study via the finite element method. Methods: Twelve 3D finite element models of a mandibular posterior segment were designed and included the first molar, a mini-implant, the periodontal ligament, and spongy and cortical bone. They were similar except for the mini-implant position and diameter (1.3, 1.6, and 2.2 mm). A vertical force of 300 N was applied to the occlusal molar surface. The von Mises stress and energy produced by the applied occlusal forces were assessed in the mini-implant and bone. Results: The stress findings were between 15.284 and 359.77 MPa for the mini-implants based on their diameters and locations. The mini-implant energy findings were between 0.00084 and 0.258 mJ. These ranges for bone stress and energy changes were 17.611 and 129.45 MPa and 0.296 and 1.575 mJ, respectively. Conclusion: A decrease in the distance between the mini-implant and tooth root has a direct effect on different parameters to explain mini-implant loosening. ORTHODONTICS (CHIC) 2012;13:e51–e57.

Key words: absolute anchorage, finite element method, mini-implant loosening

Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files.
This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site
to get your copy of Adobe Acrobat Reader.
  © 2013 Quintessence Publishing Co, Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog