Home Subscription Services
 
   

 
Quintessence International
QI Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTube
Quintessence Publishing: Journals: QI
Quintessence International

Edited by Eli Eliav

ISSN 0033-6572 (print) • ISSN 1936-7163 (online)

Publication:
May 2011
Volume 42 , Issue 5

Back
Share Abstract:

Aerial Dispersal Of Blood-Contaminated Aerosols During Dental Procedures

Hidefumi Yamada, DDS/Kohji Ishihama, DDS, PhD/Kouichi Yasuda, DDS, PhD/Yoko Hasumi-Nakayama, DDS, PhD/Shigehiro Shimoji, DDS/Kiyofumi Furusawa, DDS, PhD

Pages: 399405
PMID: 21519559

Objectives: Dental procedures with high-speed instruments produce large amounts of aerosols. The present study aimed to clarify whether blood-contaminated aerosols were existent and floating in air during dental procedures and to evaluate the effect of an extraoral evacuator system. Method and Materials: An extraoral evacuator system with a test filter was used for sample collection at distances from 50 cm (n = 102) and 100 cm (n =124) behind the patient. A leucomalachite green presumptive test was performed on the test filter. One or more positive reactions on the test filter was considered a positive result, and the positive ratio in each procedure was compared. To assess the effect of the extraoral evacuator, an additional extraoral evacuator was introduced, and the positive ratio during third molar extractions at 100 cm behind the patient was compared (n = 55). Results: At 50 cm from the mouth of the patient during third molar surgery, full-crown preparation, inlay cavity (Black Class II) preparation, and scaling with an ultrasonic scaler, positive results were obtained in 92% (12/13), 70% (21/30), 35% (9/26), and 33% (11/33) of cases, respectively. At a distance of 100 cm, positive ratios sustained 90% (35/39), 48% (15/31), 29% (6/21), and 12% (4/33), respectively. When the second extraoral evacuator was utilized, the positive ratio, at a distance of 100 cm, decreased significantly from 90% (35/39) to 60% (33/55) (P = .0015, chi-square test). Conclusion: This study showed that blood-contaminated aerosols can be suspended in air, even in general dental settings, and that extraoral evacuators are useful for reducing contaminated aerosols. (Quintessence Int 2011;42:399405)

Key words: aerosol, blood, infection control, leucomalachite green, occupational infection, splatter

Full Text PDF File | Order Article

 

Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog