Home Subscription Services
 
   

 
Quintessence International
QI Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTube
Quintessence Publishing: Journals: QI
Quintessence International

Edited by Eli Eliav

ISSN 0033-6572 (print) • ISSN 1936-7163 (online)

Publication:
February 2011
Volume 42 , Issue 2

Back
Share Abstract:

The effect of filler addition on biaxial flexure strength and modulus of commercial dentin bonding systems

Marcelo Giannini, DDS, MSD, PhD/Donald Mettenburg/César Augusto Galvão Arrais, DDS, MSD, PhD/Frederick Allen Rueggeberg, DDS, MSD

PMID: 21359242

Objective: To evaluate the effects of filler addition on the biaxial flexural strength and modulus of two commercial adhesive systems. Method and Materials: The systems were either unfilled (Adper Single Bond [3M ESPE] and Prime and Bond 2.1 [Dentsply]) or filled (Adper Single Bond Plus [3M ESPE] and Prime and Bond NT [Dentsply]). Resin disks of each product (0.6 mm thick and 6.2 mm in diameter) were prepared in Teflon molds (n = 11 each group; 44 in total). The adhesive solutions were light activated with a halogen light-curing unit. The disks were stored dry in the dark 24 hours before biaxial flexural testing in a universal testing machine until fracture (1.27 mm/minute; model 5844, Instron). Data were statistically analyzed by one-way ANOVA and Tukey post hoc test at a preset alpha of 0.05. Results: Flexural strength values (MPa) (SD) were Single Bond 62 (16); Single Bond Plus 46 (15); Prime and Bond 59 (13); and Prime and Bond NT 85 (16). The flexural moduli (MPa) (SD) were Single Bond 1,026 (241); Single Bond Plus 1,180 (188); Prime and Bond 744 (146); and Prime and Bond NT 1,539 (267). Based on the results, Prime and Bond NT (filled) exhibited higher flexural strength and modulus than Prime and Bond (unfilled), while no significant difference in both parameters was noted between Single Bond and Single Bond Plus. Conclusion: Filler addition to bonding agents can increase the flexural strength and modulus; however, results are product dependent. (Quintessence Int 2011;42:e39–e43)

Key words: biaxial flexural test, bonding agents, flexural modulus, flexural strength, fillers

Full Text PDF File | Order Article

 

Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog