Home Subscription Services

Quintessence International
QI Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Author Guidelines
Submission Form
Reprints / Articles
Quintessence Publishing: Journals: QI
Quintessence International

Edited by Eli Eliav

ISSN 0033-6572 (print) • ISSN 1936-7163 (online)

July 1993
Volume 24 , Issue 7

Share Abstract:

Effects of curing tip distance on light intensity and composite resin microhardness

Pires/Cvitko/Denehy/Swift, Jr

Pages: 517-521
PMID: 8210323

Recently, simple radiometers for measuring the intensity of dental curing lights have been introduced. This study examined the relationship among light intensity measurements by three radiometers, distane of curing tip from composite resin, and resin polymerization (as indicated by microhardness). Light intensity measurements, which decreased with increasing distance from the curing tip, were strongly correlated with composite resin hardness. Reduced light intensity produced softer composite re sin particularly on the bottom of specimens (2-mm depth). The different radiometers provided similar indications of the changes in light intensity at various curing distances.

Full Text PDF File | Order Article


Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2015 Quintessence Publishing Co Inc

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog