Influence of dental glove type on the penetration of liquid through experimental perforation: A spectrophotometric analysis

Checchi/Montebugnoli/Boschi/D’Achille

Pages: 647-649
PMID: 7568719

This study was made to assess whether the physical structure or the commercial make of a glove has any influence on the penetration of liquid through perforations in the glove during work. A comparison was made between three types of gloves (10 for each brand name and type): vinyl (Peha Fit, Paul Hartmann), latex (without ASTM certification), and Biogel D (Regent Dental Division) for a total of 30 gloves. Of the 10 gloves for each type, five were worn tightly adhering to the operator’s hand and five were worn relatively loosely. Holes of a predetermined size (.040 mm) were made in each glove on the index, middle, and ring fingers, for a total of 90 holes. A randomized preprogrammed list ensured a perfect balance of the three variables: type of glove, adherence to the hand, and fingers having holes. The amount of liquid that penetrated the gloves through the holes was determined by placing the gloved hand in a tank containing a colored substance for 3 minutes and then analyzing the colored substance that had penetrated the glove with an ultraviolet (UV) spectophotometer. The results clearly showed that the amount of liquid that penetrated through the holes varied significantly (p < 0.001) according to the type of glove tested. The mean quantity of liquid penetrating the vinyl gloves (6.24 uL) was approximately five times higher than that of the latex gloves (1.20 uL), and 100 times higher than that of the Biogel D gloves (0.05 uL). The statistical differences between the three types of gloves were even more significant in the cases in which the glove adhered closely to the hand (12.44 uL in vinyl, 2.37 uL in latex, and 0.09 uL in Biogel D), whereas no significant difference was found when the gloves were loose (0.03 uL in vinyl, 0.04 in latex, and 0.00 uL in Biogel D).

Full Text PDF File | Order Article

 

Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog