Home Subscription Services
 
   

 
Quintessence International
QI Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTube
Quintessence Publishing: Journals: QI
Quintessence International

Edited by Eli Eliav

ISSN 0033-6572 (print) • ISSN 1936-7163 (online)

Publication:
August 1998
Volume 29 , Issue 8

Back
Share Abstract:

In vivo color stability of resin composite veneers and acrylic resin teeth in removable partial dentures

Rosentritt/Esch/Behr/Leibrock/Handel

Pages: 517-522
PMID: 9807133

Objective: The color stability of laboratory-made composite veneers was compared to that of artificial resin teeth under in vivo conditions. Method and materials: Veneers and resin teeth of removable partial dentures were measured colorimetrically with reflection spectrophotometry; the color changes were characterized in the Commission Internationale d’Eclairage L*a*b* color space. The color was first determined 24 hours after manufacture and again after 6, 12, and 18 months at incisal, cervical, and centrofacial tooth positions. The denture teeth and veneers were measured, cleaned to eliminate the influence of surface discoloration, and measured again at every recall. The food consumption and tooth cleaning habits of the patients were taken into account. Results: In all groups the maximum color changes from the baseline measurement were AL* = 2.1, Aa* = 0.4, and Ab* = 1.8. The changes in the AE* values were between 1.0 and 2.5 units. Despite polishing, the AE* values increased by approximately 0.2 to 0.3 units in relation to the previous measurement with increased wearing time. External discolorations were eliminated by polishing, depending on the type of material; the maximum color change because of polishing was between 0.8 and 2.0 units for AE*. The resin teeth showed no significant changes in the AE* values. Conclusion: After a wearing period of 18 months, the discolorations of the tested materials were clinically acceptable. The artificial resin teeth showed statistically smaller color changes than did the veneering materials

Full Text PDF File | Order Article

 

Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog