Influence of the implant abutment on the Periotest value: An in vivo study

German Gomez-Roman, DMD/Dieter Lukas, MSc

Pages: 797-799
PMID: 11820048

Objective: Periotest values for dental implants depend on the type of prosthetic abutment utilized for the restoration. If Periotest value cannot be measured at the single crown, the Periotest values used for comparison must be derived from the same type of superstructure. Method and materials: Fifty-nine patients were selected from a regular follow-up program. At the end of the healing period, the Periotest values of Frialit-2 implants were measured at the gingiva former and abutment. The values were then compared with the Periotest measurements obtained at the placement of the final single crown and during the first follow-up examination. Results: Compared to values measured at single crowns, the Periotest value measured at gingiva formers decreased on average by 3.5. The measurement of the abutment revealed a decrease of 1.7. Until the first recall and under functional loading of implants, the Periotest value increased on average by 1.8. These differences significantly differed from 0. Conclusion: If measurements at different abutments such as crown abutments or single crowns are necessary, comparison of the Periotest values in accordance with the given mean values will lead to more precise results. It is recommended that Periotest measurements be performed for the first and subsequent prostheses, during all prosthetic stages, to allow comparison if some parts of the prosthetic abutment have to be replaced.

Full Text PDF File | Order Article

 

Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog