Home Subscription Services
 
   

 
Quintessence International
QI Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTube
Quintessence Publishing: Journals: QI
Quintessence International

Edited by Eli Eliav

ISSN 0033-6572 (print) • ISSN 1936-7163 (online)

Publication:
November/December 2001
Volume 32 , Issue 10

Back
Share Abstract:

Clearance of biofilms from dental unit waterlines through the use of hydroperoxide ion–phase transfer catalysts

Paul A. Shepherd, DMD, MS/Maria A. Shojaei, DMD, MS/Paul D. Eleazer, DDS, MS/Arthur Van Stewart, DMD, PhD/Robert H. Staat, PhD, MS

Pages: 755-761
PMID: 11820043

Objectives: The purpose of this research was to demonstrate the effectiveness of hydroperoxide ion–phase transfer catalyst (HPI-PTC) cleaners and disinfectants for maintaining dental unit waterlines free of planktonic organisms. Method and materials: Water samples were taken from 117 sites, which included a variety of dental units and samples from the sink faucets of most operatories. Samples were plated on appropriate bacteriologic media and incubated. The presence or absence of biofilms was confirmed by scanning electron microscopy. Twenty-two of the dental units were retrofitted with independent water systems; the cleaning procedure involved an overnight application of an HPI-PTC cleaner followed by a 2-minute water rinse. Results: Water from both the air-water syringe and the high-speed handpiece lines from all untreated units contained at least 6x102 colony-forming units per milliliter of planktonic or free-floating bacteria; the average was 1.4x105 CFU/mL. An initial 5% solution of HPI-PTC successfully cleared the lines of any apparent biofilm when applied for 3 consecutive days. Thereafter, once weekly use of the cleaner maintained the dental unit water supplies free of significant numbers of planktonic organisms. Conclusion: Routine weekly use of an HPI-PTC cleaner controlled dental unit waterline biofilm and reduced, with minimum effort, the microbial contamination level of water used for patient treatment to less than 200 CFU/mL.

Full Text PDF File | Order Article

 

Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog