Home Subscription Services
 
 
Loading
NEW
Sign Up to Receive Quintessence Updates by Email
 

 
Quintessence International
QI Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTubeRSS
Quintessence Publishing: Journals: QI
Quintessence International

Edited by Eli Eliav

ISSN 0033-6572 (print) • ISSN 1936-7163 (online)

Publication:
October 2009
Volume 40 , Issue 9

Back
Share Abstract:

The effect of finish line curvature on marginal fit of all-ceramic CAD/CAM crowns and metal-ceramic crowns

Jianxiang Tao, DDS, PhD/Dongwei Han, DDS, PhD

Pages: 745–752
PMID: 19862401

Objectives: To investigate the effect of abutment finish line curvature on the fit of all-ceramic CAD/CAM crowns and metal-ceramic crowns. Method and Materials: Three types of finish line curvature abutments (1-, 3-, and 5-mm curvature) were prepared on typodont maxillary central incisors. For each type of abutment, 5 all-ceramic crowns (Cercon system, DeguDent) and 5 metal-ceramic crowns were fabricated. The marginal gaps of copings and veneered crowns were measured on a profile projector. The data were calculated and analyzed with 2-way ANOVA and Tukey HSD test (a = .05). Results: The mean labial, lingual, mesial, and distal marginal gaps (SD) of all-ceramic crowns were similar: respectively, 54 (10), 51 (11), 47 (13), and 49 (9) µm for 1-mm curvature; 49 (12), 53 (11), 54 (10), and 55 (12) µm for 3-mm curvature; and 57 (12), 54 (11), 53 (10), and 52 (9) µm for 5-mm curvature. The mean labial, lingual, mesial, and distal marginal gaps (SD) of metal-ceramic crowns were 36 (7), 41 (9), 26 (8), and 28 (10) µm, respectively, for 1-mm curvature. The mean labial and lingual marginal gaps (SD) of metal-ceramic crowns for 3-mm curvature were 45 (8) and 48 (9) µm, respectively—significantly larger than mesial (P = .01 and .007) and distal (P = .03 and .02) gaps. The mean labial and lingual marginal gaps (SD) of metal-ceramic crowns for 5-mm curvature were 76 (10) and 74 (15) µm, respectively—significantly larger than mesial (P = .001 and .001) and distal (P = .001 and .001) gaps. Conclusions: The abutment finish line curvature had no significant effect on the marginal fit of all-ceramic crowns, but had a significant effect on the marginal fit of metal-ceramic crowns. (Quintessence Int 2009;40:745–752)

Full Text PDF File | Order Article

 

Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2013 Quintessence Publishing Co, Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog