Home Subscription Services
 
   

 
Quintessence International
QI Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTube
Quintessence Publishing: Journals: QI
Quintessence International

Edited by Eli Eliav

ISSN 0033-6572 (print) • ISSN 1936-7163 (online)

Publication:
October 2002
Volume 33 , Issue 9

Back
Share Abstract:

Effects of aging on the dimensional stability of custom-made mouthguards

Emile J. Waked, DDS; Thomas K. Lee, DDS; Angelo A. Caputo, PhD

Pages: 700-705
PMID: 12666896

Objective: The purpose of this investigation was to assess the effects of aging on the dimensional stability of vacuum-formed, pressure-formed, and pressure-laminated custom-made mouthguards. Method and materials: A master model representing the dental arch was fabricated in acrylic resin. Two ethylene vinyl acetate thermoplastic materials were tested: Essix (regular) and Proform (prelaminated). The model was benchmarked in five places along the curvature of the arch. The model was used to fabricate 10 specimens for each of the following groups: 1 = vacuum-formed (3-mm) Essix; 2 = vacuum-formed (4-mm) Proform; 3 = pressure-formed (3-mm) Essix; 4 = pressure-formed (4-mm) Proform; 5 = pressure-laminated (3-mm + 2-mm) Essix; 6 = pressure-laminated (3-mm + 3-mm) Essix. Die stone was poured into the newly made specimens and measured. Aging of the specimens was simulated by reproducing cleaning cycles (48 hours’ soaking in water at 60°F and brushing 100 times with a soft denture brush in soapy water at 140°F for 20 minutes). Die stone was poured into the aged specimens and measured. Initial and post-aging measurements were compared. Results: All specimens showed dimensional changes post-aging, mainly decreases. Pressure-laminated specimens showed the best dimensional stability. Conclusion: Aging induced various dimensional changes in mouthguards, depending on the materials and processing techniques used. Most of the dimensional change for all mouthguards occurred at the central incisor region, the most important area for the protection of the anterior teeth and the premaxilla. Pressure-laminated mouthguard specimens showed the smallest range of changes at the central incisor region, suggesting potentially improved fit, comfort, and protection.

Full Text PDF File | Order Article

 

Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog