Home Subscription Services
 
   

 
Quintessence International
QI Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: QI
Quintessence International

Edited by Eli Eliav

ISSN 0033-6572 (print) • ISSN 1936-7163 (online)

Publication:
June 2003
Volume 34 , Issue 6

Back
Share Abstract:

The effect of different exposure routines on the surface microhardness of a light-activated resin composite

Christopher Lynch, BDS, MFDRCSI/Noel Ray, MSc, PhD/Louise Hagan, BDS/Francis Burke, BDentSc, MSc, PhD, FDSRCSEd, FFDRCSI

Pages: 468-472
PMID: 12859091

Objectives: To compare the surface microhardness of a resin composite following exposure to a pulse-delayed activation routine and a standard continuous routine using a quartz-halogen lamp. Additionally, to assess the effect of increasing the distance between the activator light and the specimen using a continuous exposure routine. Method and materials: Disk specimens of a commercial resin composite restorative material were exposed to a quartz-halogen lamp in a three-step pulse-delayed routine. A continuous exposure was used as a control. Surface microhardness was recorded at the end of each step and at 1 hour after initial exposure. The data yielded four groups and the control (n = 15). Further specimens were exposed to the activator light held at a predetermined distance from the specimen. Results: The pulse-delayed routine yielded a progressive and significant increase in mean microhardness at the end of each step, and the maximum mean value was significantly lower than the control. The effect of increasing the exposure distance yielded a significant decrease in mean hardness number with increasing distance for the distances selected. Regression analysis indicated a positive linear relationship between microhardness and the natural logarithm of time and a negative correlation between microhardness and distance, respectively. Conclusion: The modified activation routines investigated resulted in significantly reduced surface microhardness numbers compared with the controls.

Full Text PDF File | Order Article

 

Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog