Home Subscription Services
 
   

 
Quintessence International
QI Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: QI
Quintessence International

Edited by Eli Eliav

ISSN 0033-6572 (print) • ISSN 1936-7163 (online)

Publication:
July/August 2004
Volume 35 , Issue 7

Back
Share Abstract:

In vitro evaluation of pH changes induced by calcium hydroxide liners

Koray Genšay, DDS, PhD/Figen Seymen, DDS, PhD/Senem Selv?, DDS, PhD/Basak Kiziltan, DDS

Pages: 560-562
PMID: 15259972

Objectives: Since the highly alkaline pH of calcium hydroxide is considered by many to be responsible for its biologic activity, the possible variations of pH induced by the different calcium hydroxide liners are accepted as a major concern. The aim of the present study was to determine the pH changes of five different calcium hydroxide liners and variations of pH levels at different time intervals. Method and materials: The materials tested were Dycal, Life, Calic, Dycal VLC, and Calcident 450. Samples were prepared according to manufacturer instructions and by using plastic molds; five standard samples from each material were prepared. The samples were then placed in separate vials, containing 10 mL deionized water (pH 7.0), and stored at room temperature (20░C). The pH measurements were taken 1 hour, 24 hours, 3 days, and 7 days after mixing. The pH variations of each material at the given time intervals were recorded, and the means were calculated. Results: Statistical analysis showed significantly high differences between the mean pH values induced by each material at all time intervals. The highest value for the first-hour measurement was for Dycal VLC, and the highest values for the other time intervals were for Calcident 450. The pH values of the materials exhibited statistically significant differences among all the time intervals. Conclusion: All materials changed the pH of deionized water toward alkaline.

Full Text PDF File | Order Article

 

Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog