Home Subscription Services
 
   

 
Quintessence International
QI Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTube
Quintessence Publishing: Journals: QI
Quintessence International

Edited by Eli Eliav

ISSN 0033-6572 (print) • ISSN 1936-7163 (online)

Publication:
June 2004
Volume 35 , Issue 6

Back
Share Abstract:

Comparative study of retentive anchor systems for overdentures

Carlos A. Svetlize, DDS/Enrique Fernández Bodereau, Jr, DDS, PhD

Pages: 443-448
PMID: 15202589

Objectives: This study aimed to evaluate the retention on two or four implants of eight resilient and nonresilient retentive anchors used in overdentures. Method and materials: Eight groups of retentive anchors were used: Dyna and Shiner (magnets); Dalla Bona and O-Ring (balls); Ceka Revax and Zaag attachments (studs); the cast bar (Dolder type) system with plastic clips; and the milled bars system. These specimens with their respective overdentures were prepared on two similar acrylic resin models with four implants (3.75 × 13 mm). Ten tensile strength tests (Instron) were performed on each group at a speed of 3 mm per minute. The statistical analysis (one-way analysis of variance, Tukey’s HSD test) was considered significant. Results: The pull force values ranged between 0.400 and 3.800 daN (International System of Units). There was a significant difference in retention in favor of the milled bars in comparison with the Ceka Revax, Hader bars, Zaag attachments, O-Ring, and Dyna groups, and a marginally significant difference compared with the Dalla Bona group. There was a highly significant difference with the Shiner magnets. Conclusion: The milled bar system was the most retentive anchor, with the Dalla Bona, Ceka Revax, Hader Bar, Zaag attachment, and O-Ring groups being the second most retentive. The least retentive groups were the Shiner and Dyna magnets. Proper abutment placement in the mandible and the correct selection of the retentive anchor will improve overdenture retention.

Full Text PDF File | Order Article

 

Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog