Home Subscription Services
 
   

 
Quintessence International
QI Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTube
Quintessence Publishing: Journals: QI
Quintessence International

Edited by Eli Eliav

ISSN 0033-6572 (print) • ISSN 1936-7163 (online)

Publication:
June 2007
Volume 38 , Issue 6

Back
Share Abstract:

Microleakage study of 3 porcelain repair materials by autoradiography

Figen Demirel, DDS, MS, PhD / Mehmet Muhtarogullari DDS, MS, PhD / Gulsen Yuksel DDS, MS, PhD / Cihat Cekic, DDS, MS, PhD

PMID: 17625615

Objective: The purpose of this investigation was to test the microleakage of 3 porcelain repair systems intended for intraoral resin-to-porcelain and resin-to-metal bonding by autoradiography. Method and Materials: Sixty alloy and 60 porcelain disks (10-mm diameter and 2-mm thickness) were prepared. Manufacturer’s directions were followed for surface treatment of specimens. Each repair material was applied on 20 alloy specimens and 20 porcelain specimens. Specimens were thermocycled by dipping them in water for 1 minute at 4 ± 2°C and 58 ± 2°C for 500 cycles. Leakage was demonstrated by the presence of radioactive isotope at the interface between the repair material and the alloy (or porcelain) as registered by autoradiography. Before testing, specimens were stored in distilled water at 37°C for 24 hours and then thermocycled. Mann-Whitney U test was used to identify the differences. Results: For the alloy groups, differences between Newbond/Clearfil Lustre and GoldLink 2/Ultrabond were significant (P < .05). For the ceramic groups, differences between Cerinate Prime/Ultrabond, Clearfil Lustre/Newbond, Cerinate Prime/Ultrabond, and Silibond/Charizma were significant (P < .05). Conclusions: For the porcelain groups, the amount of microleakage in Ultrabond/Cerinate Prime was significantly higher than the other groups. For the alloy groups, all samples showed leakage. (Quintessence Int 2007;38:525.e285–290)

Key words: alloy, autoradiography, composite, intraoral repair, microleakage, porcelain repair materials

Full Text PDF File | Order Article

 

Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog