Home Subscription Services
 
   

 
Quintessence International
QI Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: QI
Quintessence International

Edited by Eli Eliav

ISSN 0033-6572 (print) • ISSN 1936-7163 (online)

Publication:
April 2007
Volume 38 , Issue 4

Back
Share Abstract:

Retrospective study of 200 immediately loaded implants retaining 50 mandibular overdentures

Marco Degidi, MD, DDS / Adriano Piattelli, MD, DDS / Giovanna Iezzi, DDS / Francesco Carinci, MD, DDS

Pages: 281288
PMID: 17432782

Objective: To perform a retrospective study on immediately loaded implants supporting mandibular overdentures. Method and Materials: From the period between July 1996 and October 2004, 50 patients were selected in whom 200 implants had been inserted (4 implants per patient) in the interforaminal area, rigidly connected with a U-shaped bar, and then loaded with a mandibular overdenture. Implant diameter and length ranged from 3.4 to 5.5 mm and from 10.0 to 18.0 mm, respectively. Sixty implants were placed after extraction, and bone quality was D1 in 22 cases and D2 in 178 cases. Because no implants were lost (ie, survival rate, 100%) and no statistical differences were detected among the studied variables, no or reduced crestal bone resorption was considered as an indicator of success rate to evaluate the effect of several host-, surgery-, and implant-related factors. A general linear model was then performed to detect those variables statistically associated with crestal bone resorption. Results: No implants were lost (ie, survival rate, 100%) after a mean postloading follow-up of 43 months, and thus no differences were detected among the studied variables. On the contrary, the general linear model showed that longer (ie, length > 13.0 mm) and wider (ie, diameter > 3.75 mm) implants and implant type (Frialoc and XiVE TG) are correlated with a lower crestal bone resorption and thus a better outcome. Conclusion: Immediate loading of implants retaining a mandibular overdenture is a reproducible, predictable, and reliable method to deliver efficient return of function for totally edentulous patients. (Quintessence Int 2007;38:281288)

Key words: general linear model, immediate loading, implants, overdenture

Full Text PDF File | Order Article

 

Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog