The marginal fit of porcelain veneers on titanium copings: An in vitro study

Sorin Lakatos, DMD, PhD / Mihai Romīnu, DMD, PhD / Zeno Florita DMD / Camil Ianes DMD / Meda Negrutiu, DMD, PhD

PMID: 17510727

Objectives: To compare the cervical microleakage of titanium copings veneered with 3 porcelain-based materials with that of titanium copings veneered with 2 indirect polymeric materials. Method and Materials: Commercially pure, grade 2 titanium was veneered with 3 porcelain systems specially designed for fusing on titanium: Ti22 (Noritake), Triceram (Esprident), and Vitatitankeramik (Vita). Additionally, 2 polymeric materials were used for veneering titanium: Chromasit and Targis (Ivoclar). Four veneer crowns for each titanium-veneer combination were obtained. After storing the specimens in basic fuchsin, the microleakage between titanium and veneer in the cervical area was assessed by measuring the extent of dye penetration within the interface. ANOVA and post hoc statistics were used to analyze the data. Results: Chromasit exhibited the highest mean microleakage score (3 ± 0.816). The least mean microleakage at the interface was recorded for Ti22 porcelain (0 ± 0.0), followed by Triceram (0.25 ± 0.50), Vitatitankeramik (0.75 ± 0.957), and Targis (1.5 ± 1.732). Only the differences between each porcelain system and Chromasit were significant (P < .05). Conclusion: Within the limitations of this in vitro study, there was no significant microleakage between titanium copings and the porcelain veneers, regardless of the porcelain system. The microleakage between titanium and the polymeric materials depended on the veneering material. Leakage was significantly higher when Chromasit was used. (Quintessence Int 2007;38:173.e169–175)

Key words: interface, microleakage, polymeric material, porcelain, titanium

Full Text PDF File | Order Article


Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2015 Quintessence Publishing Co Inc

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog