Home Subscription Services
 
   

 
Quintessence International
QI Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: QI
Quintessence International

Edited by Eli Eliav

ISSN 0033-6572 (print) • ISSN 1936-7163 (online)

Publication:
February 2007
Volume 38 , Issue 2

Back
Share Abstract:

Clinical evaluation of different gingival retraction cords

Ovul Kumbuloglu, DDS, PhD / Atilla USER, Prof Dr / Suna Toksavul, Prof Dr / Hayal Boyacioglu

PMID: 17510720

Objectives: Impression techniques in restorative dentistry require displacement of gingival tissues to expose subgingival finish lines on tooth preparations. Retraction cords are commonly used for this purpose. Some cord systems include various medicaments, which may remain in the sulcus after retraction procedures. The purpose of this study was to determine whether any of the commonly used gingival retraction medicaments could influence the surface characteristics of the impression material and to evaluate the clinical performance of retraction cords. Method and Materials: Sixteen cord systems in various shapes, sizes, and medications were used in this study. The clinical performances of cords were evaluated with a blind experimental study design, according to predetermined criteria. Results were analyzed by using chi-square test and ordinal logistic regression analysis (P < .05). Results: Statistically significant differences were found in all criteria among groups (P < .05). None of the materials investigated appeared to have any influence on the surface characterization of the polyvinyl siloxane impression material used. Better impression qualities were observed in groups with easy insertion, proper dilatation, less recurrent bleeding, and no remnants or fraying. Logistic regression analysis revealed that both retraction cord medicaments (odds ratio = 0.63, P = .00 < .05) and cord thicknesses (odds ratio = 2.09, P = .00 < .05) were important risk factors on the gingival margin quality. Conclusions: The applied gingival retraction cord systems had no influence on the surface characterization of the polyvinyl siloxane material tested. Gingival margin quality of the impression and clinical application procedures were affected by the retraction systems. Untreated, medium-braided, and epinephrine-impregnated cord systems were clinically successful. However, the potential systemic effects of epinephrine must be considered. (Quintessence Int 2007;38:91.e9298)

Key words: medicament, polyvinyl siloxane, retraction cord

Full Text PDF File | Order Article

 

Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog