Home Subscription Services
 
   

 
Quintessence International
QI Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTube
Quintessence Publishing: Journals: QI
Quintessence International

Edited by Eli Eliav

ISSN 0033-6572 (print) • ISSN 1936-7163 (online)

Publication:
January 2007
Volume 38 , Issue 1

Back
Share Abstract:

Influence of impression material and time on the 3-dimensional accuracy of implant impressions

Stefan Holst, PhD, DMD, Priv-Doz Dr med dent / Markus B. Blatz, DMD, Dr med dent / Michael Bergler, MDT / Matthias Goellner / Manfred Wichmann, PhD, DMD, Prof Dr med dent

Pages: 6773
PMID: 17216911

Objective: To investigate, in vitro, the effect of time on the 3-dimensional accuracy of open-tray implant impression copings made of polyvinyl siloxane and polyether impression materials. Method and Materials: Reference models with 4 internal connection implants were fabricated. Four sets of 71 direct impressions were made with square impression copings using an open-tray technique. One set of impressions was made with polyether material (material A) and each of 3 polyvinyl siloxane materials (materials B, C, and D). Three-dimensional changes in spatial orientation of the implant analogs were measured over 48 hours using an optical measurement device. Deviation values were summed over 4 points and averaged per impression. Global differences were tested with a nonparametric Kruskal-Wallis test followed by pairwise comparisons using the Mann-Whitney U test. Results: The mean dimensional accuracy of implant impressions significantly differed over time (P < .001). Materials A and B were found to produce comparable results. For materials C and D there was a significant increase in deviations, with a maximum increase at 2 hours. Deviations for material C were comparable to materials A and B at 48 hours. Baseline values were not maintained by any material. Conclusions: Within the limits of this in vitro study, it can be concluded that time cannot be neglected as a factor affecting the accuracy of implant master casts. (Quintessence Int 2007;38:6773)

Key words: dental implant, impression material, master cast, optical measurement, polyether, polyvinyl siloxane, precision, three-dimensional distortion

Full Text PDF File | Order Article

 

Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog