Home Subscription Services
 
   

 
Quintessence International
QI Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: QI
Quintessence International

Edited by Eli Eliav

ISSN 0033-6572 (print) • ISSN 1936-7163 (online)

Publication:
September 2006
Volume 37 , Issue 8

Back
Share Abstract:

Effect of instrument lubricant on the cohesive strength of a hybrid resin composite

Jorge Perdigão, DMD, MS, PhD / George Gomes, DMD

Pages: 621–625
PMID: 16922021

Objectives: The purpose of this study was to evaluate the effect of instrument lubricant on the cohesive strength of resin composite layers. Method and Materials: Clear acrylic molds were filled with 3 increments of a hybrid resin composite using a metal instrument. The first increment (shade A2) was inserted to a height of 4 mm and light cured, followed by a 1-mm-high second increment (shade A1). The composite instrument was then wiped with 1 of 7 lubricants before insertion of a 1-mm-high third increment (shade A1): (1) isopropyl alcohol gauze, 70% v/v (AL); (2) acetone (AC); (3) Adper Single Bond Adhesive (SB); (4) One-Step Adhesive (OS); (5) D/E Bonding Resin (DE); (6) Scotchbond Multi-Purpose Adhesive (SP); (7) Tescera Sculpting Resin (TE). No lubricant was used in the control group (CT). A final 4-mm-high increment (shade A2) was inserted and light cured. The blocks were sectioned to obtain 48 sticks for each group. Sticks were fractured with an Instron machine. Statistics were computed using 1-way analysis of variance and Duncan’s test. Results: Outcomes were as follows (mean ± SD, MPa; same letters indicate significant differences at a confidence level of 95%): TE = 96.7A ± 17.8; SP = 93.6AB ± 9.6; DE = 93.4AB ± 16.2; OS = 91.9AB ± 19.5; AC = 90.1ABC ± 12.2; SB = 89.9ABC ± 14.5; AL = 88.8BC ± 16.8; CT = 84.7C ± 8.3. Conclusions: Although the difference between Tescera Sculpting Resin and alcohol was statistically significant, Tescera Sculpting Resin is recommended only for indirect composite restorations. The lubricant used to reduce stickiness between the resin composite used for direct restorations and the composite instrument did not significantly reduce bond strengths. (Quintessence Int 2006;37:621–625)

Key words: bond testing, dental bonding, resin composite

Full Text PDF File | Order Article

 

Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog