Home Subscription Services
 
 
Loading
NEW
Sign Up to Receive Quintessence Updates by Email
 

 
Quintessence International
QI Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitterYouTubeRSS
Quintessence Publishing: Journals: QI
Quintessence International

Edited by Eli Eliav

ISSN 0033-6572 (print) • ISSN 1936-7163 (online)

Publication:
January 2006
Volume 37 , Issue 1

Back
Share Abstract:

Dimensional accuracy of a new polyether impression material

Tatsuo Endo, DDS, PhD / Werner J. Finger, Dr Med Dent, PhD, Prof

Pages: 47–51
PMID: 16429703

Objectives: The purpose of this study was to evaluate the dimensional accuracy of stone dies produced from standardized impressions with 1 new and 1 conventional polyether impression material and a polyvinyl siloxane reference material. Methods and materials: Impressions with the polyether materials P2 and Impregum and with the polyvinyl siloxane Flexitime were produced at 23°C or 37°C from a truncated steel cone in cylindrical steel trays giving 4-mm impression layer thickness at the prominence line. Stone dies were poured after 1 or 24 hours of storage at ambient atmosphere. Additional impressions were stored at different relative humidity levels (0%, 33%, 50%, 75%, or 100%) for 24 hours prior to die pouring. The accuracy of the stone dies was determined as axial discrepancy between a steel ring, which fit perfectly on the steel die and the occlusal die surface. The base-diameter deviation (∆d) was calculated. Results: After 1 hour, a similar increase in ∆d was noticed for impression materials when dies were poured at impression temperature. Impressions made at 37°C exhibited significantly higher ∆d than at 23°C. Light-bodied P2 showed the highest ∆d increase when dies were poured after 24 hours. Flexitime showed moderate ∆d differences at the 2 pouring times. The ∆d of dies made from polyether materials decreased significantly with increasing humidity, whereas polyvinyl siloxane was not adversely affected. Conclusion: The dimensional accuracy of P2 is comparable to that of the conventional polyether impression material after short-term storage. Polyethers may absorb water, significantly compromising die accuracy upon storage at high humidity. (Quintessence Int 2006;37:47–51)
Key words: dimensional accuracy, elastomeric impression materials, polyether, polyvinyl siloxane, storage humidity, storage time

Full Text PDF File | Order Article

 

Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2013 Quintessence Publishing Co, Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog