Home Subscription Services
 
   

 
Quintessence International
QI Home Page
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: QI
Quintessence International

Edited by Eli Eliav

ISSN 0033-6572 (print) • ISSN 1936-7163 (online)

Publication:
March 2005
Volume 36 , Issue 3

Back
Share Abstract:

Use of laser fluorescence in monitoring the durability and cariostatic effects of fluoride and chlorhexidine varnishes on occlusal caries: A clinical study

Saadet Gokalp, DDS, PhD/Meserret Bas¸eren, DDS, PhD

Pages: 183–189
PMID: 15887503

Objective: The aim of this study was to compare the effectiveness and caries-preventive effects of a fluoride varnish (Fluor Protector; 0.1% fluoride) and a chlorhexidine varnish (Cervitec; 1% chlorhexidine and 1% thymol) on initial caries of occlusal fissures and to monitor the durability of the varnishes by the use of a fluorescence system, DIAGNOdent (Dd). Method and materials: Nineteen subjects underwent professional tooth cleaning at the beginning of the study. Afterward, fluorescence measurements (baseline) were obtained from 56 test sites and 28 control sites on the central fossae of molars. Each subject had Fluor Protector and Cervitec application on randomly assigned experimental teeth, and applications were followed by Dd measurements. Measurements were repeated after 1 and 6 months. Results: There was an increase in fluorescence values immediately after application of varnish in the two test groups. One month after varnish application, Dd scores for group Fluor Protector were not significantly different from Dd scores obtained immediately after application (P = .108), whereas Dd scores for group Cervitec decreased significantly (P = .007). For both test groups, there was a significant decrease between the values obtained immediately after application and those acquired after 6 months. There was also a significant decrease between 1 month and 6 months for test groups and a slight but significant increase for the control group (P = .011). No significant difference was found between the Fluor Protector and Cervitec groups after 6 months. Conclusion: It was concluded that the Dd system may be used to monitor the existence of these two varnishes. (Quintessence Int 2005;36:183–189)

Full Text PDF File | Order Article

 

Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog