Short-term clinical evaluation of a resin-modified glass-ionomer luting cement

Sumie Yoneda, DDS, PhD/Makoto Morigami, DDS, PhD/Jumpei Sugizaki, DDS, PhD/Toshimoto Yamada, DDS, PhD

Pages: 49 - 53
PMID: 15709497

Objectives: Resin-reinforced glass-ionomer cements were developed by adding resin components to conventional glass-ionomer cement. This improved physical properties and bonding characteristics. FujiCEM is the first paste-paste–type resin-modified glass-ionomer luting cement that enables consistent mixture. The purpose of this study was to evaluate the short-term clinical performance of FujiCEM, which was used for final cementation of indirect restorations, such as inlays, crowns, and fixed partial dentures. Method and materials: A total of 290 restorations (165 crowns, 71 inlays, 15 onlays, 36 fixed partial dentures, 3 implant superstructures) were placed in 268 patients (137 males, 131 females) with a mean age of 54.4 ± 13.0 years. Restorations were luted with FujiCEM mixed for 10 seconds after the teeth surfaces were treated with a conditioner containing 10% citric acid and 2% ferric chloride for 20 seconds, washed, and dried with gentle air flow. Out of the investigated 337 teeth, 99 (29%) teeth were vital, and 238 (71%) were nonvital. These restorations were followed up for a period of 21 months. All the restorations were evaluated for postoperative sensitivity, secondary caries, gingival condition, and pocket depth. Results: No clinical failures (eg, dislodgment, secondary caries, irritation of soft tissue, and postoperative sensitivity) were observed. Conclusion: FujiCEM had promising clinical performance with inlays, crowns, onlays, fixed partial dentures, and implant superstructures at 21 months after service.

Full Text PDF File | Order Article

 

Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2014 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog