Follow Us      

LOGIN
 
Share Page:
Back

Volume 12 , Issue 2
March/April 1992

Pages 113-121


Comparative accuracy of implant impression procedures

Assif/Fenton/Zarb/Schmitt


PMID: 1521993
DOI: 10.11607/prd.00.0006

In this study, four impression procedures were assessed for accuracy in a laboratory model that simulated clinical practice. The accuracy of stone casts with brass implant analogs was measured against a standard framework. The fit of the framework on the casts was tested by manual and visual judgment and by microscopic measurement. The measurements supported the clinical judgments. When acrylic resin was used to splint transfer copings in an impression, all casts were acceptable and were more accurate than the best of the two other procedures, which did not use an acrylic resin splint. When an impression material was used to orient the transfer copings, the accuracy was better if undercut copings remained in the impression. When impressions were made by removing an impression from smooth transfer copings and replacing the copings in the impression, the majority of casts were unacceptable.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help