Share Page:

Volume 12 , Issue 1
January/February 1997

Pages 118-124

An Experimental Analysis of the Stresses on the Implant in an Implant-Tooth--Supported Prosthesis: A Technical Note


PMID: 9048464

When a natural tooth connected to an implant abutment by a framework is displaced within physiologic limits under functional loads, the superstructure acts as a cantilever moment arm and the implant is loaded additionally during that moment effect. The effects of a deflecting support connected to an IMZ implant, with either the IMC resilient or the titanium rigid element, were evaluated through an experimental model. The strain values measured when the moment arm was not allowed to deflect were only 30% lower than the strains measured when it was deflected within the limits of physiologic tooth mobility. The IMC was effective and achieved a reduction in the cervical strains up to 60% when compared with the rigid connector.

Full Text PDF File | Order Article


Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.


© 2015 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Author Guidelines
Accepted Manuscripts
Submission Form
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us