Accuracy of Impressions for Internal-Connection Implant Prostheses with Various Divergent Angles

Hee-Kon Jang, DDS, MS/Sungtae Kim, DDS, PhD/June-Sung Shim, DDS, PhD/Keun-Woo Lee, DDS, PhD/Hong-Seok Moon, DDS, PhD


PMID: 22010084

Purpose: The aim of this study was to determine the accuracies of implant-level impressions for internal-connection dental implants with various angles of divergence. Materials and Methods: Five groups were created according to the angles of divergence (0, 5, 10, 15, and 20 degrees) between two implant analogs in a master model. A master stone model for each group was fabricated. The divergent angle in each master model was verified with a profilometer. Study models (n = 10) from each master model were constructed through the implant-level impression technique. The divergent angle in each study model was verified with the profilometer. The splinted metal framework with passive fit was cast with base metal and cast-on abutments in each master model. The metal framework was tried in the study models and the fit of each framework was evaluated. One-way analysis of variance and the Tukey Honestly Significant Difference test were used for statistical analysis. Results: Statistically significant deformations of the impressions were found in the study models with divergently placed implant analogs. A larger divergence angle resulted in a larger gap between the framework and the implant analogs. The gap in the 20-degree divergence group differed significantly from that measured in the master model (P < .01). Conclusions: Internal-connection implants were accurate when the divergence angle was less than 15 degrees. Inaccuracy of impressions increased as the divergence angle increased. The inaccuracy was significantly greater for the 20-degree-divergent implants than the other groups. Int J Oral Maxillofac Implants 2011;26:10111015

Key words: deformation of impression, divergent angle, implant impression, implant-level impressions, impression accuracy, internal-connection implant


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help