LOGIN
 
Share Page:
Back

Volume 26 , Issue 5
September/October 2011

Pages 976–984


Biomechanical Comparison of Axial and Tilted Implants for Mandibular Full-Arch Fixed Prostheses

Kyea-Soon Kim, DDS, MSD, PhD/Yu-Lee Kim, DDS, MSD, PhD/Ji-Myung Bae, DDS, MSD, PhD /Hye-Won Cho, DDS, MSD, PhD


PMID: 22010079

Purpose: Controversy exists regarding the “All-on-Four” concept for a mandibular full-arch fixed prosthesis. The purpose of this study was to examine photoelastically the effect of the inclination of the two distal implants according to the All-on-Four concept on the stress distribution within the supporting structure. Materials and Methods: Two photoelastic models of a human edentulous mandible were fabricated. Each model had four screw-type implants embedded in the interforaminal area. The two distal implants were placed axially in one model and tilted 30 degrees distally in the other model. Two cantilevered acrylic resin prostheses, which used angulated abutments for the distal tilted implants and straight abutments for the axial implants, were fabricated and delivered. Vertical loads of 13 kg were applied at three loading points on the prosthesis: the central fossa of the first molar, the distal fossa of the first premolar, and the distal fossa of the second premolar. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. Results: Whereas all cantilever loadings concentrated the stresses at the distal crest of the distal implant sites in both models, the posterior tilting of distal implants splinted in a full-arch fixed prosthesis did not increase the stresses in bone around the distal implants versus the axial-implant model. Conclusion: Within the limitations of this photoelastic stress analysis, the use of tilted implants reduced the maximum stress in the distal crestal bone of the distal implant by approximately 17% relative to the axial implants. Int J Oral Maxillofac Implants 2011;26:976–984

Key words: All-on-Four concept, mandibular full-arch fixed prosthesis, photoelastic stress analysis, tilted implant


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help