LOGIN
 
Share Page:
Back

Volume 26 , Issue 5
September/October 2011

Pages 961–969


Three-Dimensional Finite Element Analysis of Titanium and Yttrium-Stabilized Zirconium Dioxide Abutments and Implants

Alper Çaglar, DDS, PhD/Bilge Turhan Bal, DDS, PhD/Seçil Karakoca, DDS/Cemal Aydın, DDS, PhD/Handan Yılmaz, DDS, PhD/Senol Sarısoy, DDS


PMID: 22010077

Purpose: The purpose of this study was to compare the von Mises (vM), compressive, and tensile stresses occurring on implants, abutments, and surrounding bone using three-dimensional finite element analysis (FEA) in three simulations in the anterior maxilla: a single titanium implant with a titanium abutment, a single titanium implant with a zirconia abutment, and a single one-piece zirconia implant. Materials and Methods: Three types of implants (all were 4 × 12 mm) were modeled using FEA: Astra OsseoSpeed implant with titanium abutment (ATt), Astra OsseoSpeed with zirconia abutment (ATz), and White-SKY (WS) one-piece zirconia dental implant. The anterior maxillary bone was also simulated with FEA. The implants were placed into the maxillary left central incisor region. Loading was applied horizontally and obliquely and the stresses were examined. Results: The vM and compressive stresses that occurred on the implant and cortical bone in the ATz model were lower than those seen in the ATt model. The tensile stress values observed in the abutment and cortical bone in the ATz and ATt models and all the stress values occurring in trabecular bone were similar. The stresses that occurred in the WS implant were lower than the stresses exerted on the ATt and ATz implants, except for tensile stresses under oblique loading. Conclusion: Lower stresses occurred on the zirconia implant (WS), except for tensile stress under oblique loading. The zirconia implant generated the lowest stresses in cortical bone, and the zirconia abutment resulted in lower vM and compressive stresses than the titanium abutment in implant and cortical bone. Int J Oral Maxillofac Implants 2011;26:961–969

Key words: dental implants, finite element analysis, implant abutments, stress/strain, titanium, zirconia


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help