The Effects of Laser Microtexturing of the Dental Implant Collar on Crestal Bone Levels and Peri-implant Health

Spyros Botos, DDS, MSD/Hoda Yousef, DMD, MS/Barry Zweig, DDS/Robert Flinton, DDS, MS/Saul Weiner, DDS


PMID: 21691595

Purpose: Polished and machined collars have been advocated for dental implants to reduce plaque accumulation and crestal bone loss. More recent research has suggested that a roughened titanium surface promotes osseointegration and connective tissue attachment. The purpose of this research was to compare crestal bone height adjacent to implants with laser-microtextured and machined collars from two different implant systems. Materials and Methods: Four implants, two with laser-microtextured collars and two with machined collars, were placed in the anterior mandible to serve as overdenture abutments. They were placed in alternating order, and the distal microtextured- and machined-collar implants were loaded with ball abutments. The mesial implants were left unloaded. The distal implants were immediately loaded with prefabricated dentures. Plaque Index, Bleeding Index, and probing depths (PDs) were measured after 6 and 12 months for the loaded implants. Bone loss for both groups (loaded and unloaded) was evaluated via standardized radiographs. Results: Plaque and bleeding values were similar for both implant types. The microtextured-collar implants showed shallower PDs (0.36 0.5 mm and 0.43 0.51 mm) than those with machined collars (1.14 0.77 mm and 1.64 0.93 mm; < .05 for 6 and 12 months, respectively). At 6 and 12 months, respectively, the microtextured implants showed less crestal bone loss for both loaded (0.19 0.15 mm and 0.42 0.34 mm) and unloaded groups (0.15 0.15 mm and 0.29 0.20 mm) than the machined implants for both the loaded (0.72 0.5 mm and 1.13 0.61 mm) and unloaded groups (0.29 0.28 mm and 0.55 0.32 mm). Conclusion: Application of laser-microtextured grooves to the implant collar resulted in shallower PDs and less peri-implant crestal bone loss than that seen around implants with machined collars. Int J Oral Maxillofac Implants 2011;26:492498

Key words: biologic width, crestal bone, implant collar, tissue engineering


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help