Load-Bearing Capacity of Custom-Made Versus Prefabricated Commercially Available Zirconia Abutments

Jenni Hjerppe, DDS, PhD/Lippo V. J. Lassila, DDS/Tero Rakkolainen, CDT/Timo Närhi, DDS, PhD/Pekka K. Vallittu, DDS, PhD


PMID: 21365048

Purpose: To compare the load-bearing capacity of custom-made zirconia abutments with that of prefabricated commercially available zirconia abutments. Materials and Methods: Zirconia (ICE Zircon) blocks were manually copy-milled to abutments using prefabricated commercially available abutments as models, divided into four groups (n = 10/group), and sintered at 1,500°C. Prefabricated commercially available abutments were used as controls (groups 1 and 4, n = 10/group). The abutments in the study groups were: (1) Astra ZirDesign (AstraTech); (2) copy-milled Zirkonzahn-Astra; (3) copy-milled Zirkonzahn-Astra, short; (4) Xive Cercon (Dentsply/Friadent); (5) copy-milled Zirkonzahn-Xive; and (6) copy-milled Zirkonzahn-Xive, modified. Seven abutments per group were screwed onto implant replicas (size 3.5/4.0 mm for AstraTech, 3.8 mm for Dentsply Friadent) with acrylic resin sample base; the implants were loaded dry with a universal testing machine at room temperature and a 45-degree loading angle. Statistical analyses were made using one-way analysis of variance. The three remaining abutments per group were screwed onto implant replicas, and the distance between the replica and the abutment was measured with a scanning electron microscope. Results: Significant differences were seen among the groups in terms of load-bearing capacity; copy-milled Zirkonzahn-Xive modified abutments (group 6) were statistically significantly stronger (1,099 N) than the other abutments (P < .05). The Xive models resulted in catastrophic failure, whereas the Astra-design revealed visual bending before failure. Conclusions: Custom-made zirconia abutments have comparable failure loads to those seen for prefabricated commercially available zirconia abutments. Int J Oral Maxillofac Implants 2011;26:132–138

Key words: custom-made abutment, dental abutment, load-bearing capacity, marginal fit, zirconia


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help