LOGIN
 
Share Page:
Back

Volume 25 , Issue 4
July/August 2010

Pages 763770


Bone Stress Analysis of Various Angulations of Mesiodistal Implants with Splinted Crowns in the Posterior Mandible: A Three-Dimensional Finite Element Study

Ting-Hsun Lan, DDS, MDS/Chin-Yun Pan, DDS, MDS/Huey-Er Lee, DDS, MS, PhD/Heng-Li Huang, MS, PhD/Chau-Hsiang Wang, DDS, MDS, PhD


PMID: 20657872

Purpose: Ideally, implants for dental prostheses should be placed parallel to each other. However, anatomic limitations sometimes make nonparallel implants necessary. The purpose of this study was to determine the bone stresses on implants tilted at various angles and to determine what arrangements might carry a higher risk of failure. Materials and Methods: Three-dimensional finite element models were constructed using the mean values measured for the Asian mandible in the first and second molar areas. Eight implants were divided into three tilting types: parallel implants (P1PP, P2MM, and P3DD), convergent implant apices (C1PD and C2MP), and divergent implant apices (D1DP, D2DM, and D3PM). A biting load of 200 N was applied vertically and obliquely on the occlusal central fossa of the splinted crowns. The main effects of each level of the three investigated factors (loading type, relationship of implant apices, and distal tilting of one or both implants) in terms of the stress values were computed for all models. Results: The loading type was the main factor affecting the stress in bone when comparing implant apices and distal tilting of the implant body. When loading was combined with distal tilting, the stress values were significantly increased, especially in models P3DD and C1PD. Conclusion: The loading type is the main factor affecting the stress distribution for different implantation arrangement. Moreover, placement of the implants with distal tilting should be avoided in the posterior mandible. Int J Oral Maxillofac Implants 2010;25:763770

Key words: convergent implant apices, divergent implant apices, finite element analysis, implant axis, implant loading


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help