Impact of Abutment Rotation and Angulation on Marginal Fit: Theoretical Considerations

Wiebke Semper, DDS/Silvan Kraft, MSc/Jrgen Mehrhof, MDT/Katja Nelson, DDS, PhD


PMID: 20657870

Purpose: Rotational freedom of various implant positional index designs has been previously calculated. To investigate its clinical relevance, a three-dimensional simulation was performed to demonstrate the influence of rotational displacements of the abutment on the marginal fit of prosthetic superstructures. Materials and Methods: Idealized abutments with different angulations (0, 5, 10, 15, and 20 degrees) were virtually constructed (SolidWorks Office Premium 2007). Then, rotational displacement was simulated with various degrees of rotational freedom (0.7, 0.95, 1.5, 1.65, and 1.85 degrees). The resulting horizontal displacement of the abutment from the original position was quantified in microns, followed by a simulated pressure-less positioning of superstructures with defined internal gaps (5 m, 60 m, and 100 m). The resulting marginal gap between the abutment and the superstructure was measured vertically with the SolidWorks measurement tool. Results: Rotation resulted in a displacement of the abutment of up to 157 m at maximum rotation and angulation. Interference of a superstructure with a defined internal gap of 5 m placed on the abutment resulted in marginal gaps up to 2.33 mm at maximum rotation and angulation; with a 60-m internal gap, the marginal gaps reached a maximum of 802 m. Simulation using a superstructure with an internal gap of 100 m revealed a marginal gap of 162 m at abutment angulation of 20 degrees and rotation of 1.85 degrees. The marginal gaps increased with the degree of abutment angulation and the extent of rotational freedom. Conclusions: Rotational displacement of the abutment influenced prosthesis misfit. The marginal gaps between the abutment and the superstructure increased with the rotational freedom of the index and the angulation of the abutment. Int J Oral Maxillofac Implants 2010;25:752758

Key words: abutment rotation, marginal gap, prosthesis misfit, three-dimensional simulation


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help