LOGIN
 
Share Page:
Back

Volume 25 , Issue 4
July/August 2010

Pages 729743


The Effect of Increased Crown-to-Implant Ratio on Single-Tooth Locking-Taper Implants

Rainier A. Urdaneta, DMD, CAGS/Sujey Rodriguez, DDS, MS/D. Cary McNeil, DDS, MS/Meghan Weed, RDH/Sung-Kiang Chuang, DMD, MD, DMSc


PMID: 20657868

Purpose: It has been proposed that increased crown heights lead to greater crestal stresses on dental implants, crestal bone loss, and other complications. The purpose of this study was to evaluate the effect of increased crown-to-implant ratio (C/IR) on single-tooth implants. Materials and Methods: A retrospective cohort study was conducted between July 2001 and August 2003. The cohort was composed of patients who had at least one single-tooth Bicon implant restored with a cementless restoration and attended recall examinations in 2004, 2005, and 2007, during which several clinical and radiographic variables were documented. Descriptive statistics and univariate and multivariate mixed-effects regression models, adjusted for multiple implants in the same patient, were used. Results: The cohort was composed of 81 subjects who received 326 Bicon implants. The mean duration of follow-up was 70.7 months. Mean change in the mesiodistal crestal bone levels was 0.33 mm. The mean C/IR was 1.6 (range, 0.79 to 4.95). Forty implant restorations (16%) had a C/IR ≥ 2. Implant restorations with increased C/IR were significantly more likely to have increased mesiodistal crown width, larger implant diameter, larger distance to mesial and distal adjacent structures, and deeper sulcular probings. Increased C/IR had a statistically significant effect in the loosening of maxillary anterior Integrated Abutment Crowns (Bicon) as well as a significant effect in the fracture of 2-mm-wide titanium abutment posts used to restore posterior areas. A C/IR up to 4.95 did not lead to an increased risk of crestal bone loss or to an increase in implant failures, crown failures, or crown fractures. Conclusion: Larger C/IR was associated with a significant increase in prosthetic complications but had no significant effect on crestal bone levels on single-tooth locking-taper implants. Int J Oral Maxillofac Implants 2010;25:729743

Key words: cementless restorations, crown-to-implant ratio, plateau design dental implants, resin crowns, stress


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help