Purpose: The present study evaluated implant and peri-implant outcomes as well as prosthodontic maintenance efforts for implant/bar-supported mandibular prostheses with different prosthesis anchorage systems. Materials and Methods: Seventy-six patients who received two or four interforaminal implants were assigned to one of three different bar designs and subsequently to different prosthesis supporting systems. Forty-nine patients received implants and a mucosa-supported implant-retained overdenture (OD) with an ovoid bar (two implants; design 1) or multiple ovoid bars (four implants; design 2). Twenty-seven patients received four implants and a rigid implant-supported prosthesis (ISP) with a milled bar (design 3). Implant survival, peri-implant parameters (marginal bone resorption, pocket depth, and plaque, bleeding, gingival, and calculus indices), and postinsertion prosthodontic maintenance were followed over a 5-year period and compared among the different retention modalities. At the most recent follow-up examination, subjective patient satisfaction was additionally evaluated using a simplified scoring system (ranging from 1 = not satisfactory to 5 = excellent). Results: Implant survival rates (100%) and all peri-implant parameters evaluated showed no differences among the three designs used for implant prosthesis anchorage. Prosthodontic maintenance did not differ between the different ODs (OD design 1: average of 1.04 maintenance visits/year/patient; OD design 2: 1.2 maintenance visits/year/patient), but it was significantly lower for the dentures that were rigidly stabilized with milled bars (ISP: 0.37 maintenance visits/year/patient). A high subjective satisfaction rate (range: 4.5 to 5.0) was registered at the final examination, without any differences among the designs used. Conclusions: Rigid anchorage with milled bars on four-implant prostheses combined with a metal-reinforced framework showed a lower extent of prosthodontic maintenance issues than round bars on two- or four-implant overdentures with resilient denture stabilization. Nevertheless, implants and peri-implant structures were not negatively affected by either resilient or rigid anchorage mechanisms. Int J Oral Maxillofac Implants 2010;25:589–597


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help