LOGIN
 
Share Page:
Back

Volume 25 , Issue 3
May/June 2010

Pages 455460


Microgap Between Zirconia Abutments and Titanium Implants

Sebastien Baixe, DMD/Gabriel Fauxpoint, DMD/Youri Arntz, PhD/Olivier Etienne, DMD, PhD


PMID: 20556243

Purpose: The aim of this study was to evaluate in vitro the microgap between different zirconia abutments and their titanium implants. Materials and Methods: Four systems were evaluated: Procera zirconia (Nobel Biocare) (Nb), Cercon Balance Anterior (Dentsply Friadent) (Ba), ZirDesign (Astratech) (Zd), and Straumann Cares ceramic (Straumann) (Ca). Five assemblies were assessed for each system. The assemblies were embedded in epoxy, cut along their long axes, and polished. Scanning electron microscopic observations were made along the first 100 m of the gap on each side at maximal magnification. Images were combined and gap measurements were made 10 m apart. A two-way analysis of variance was performed on the data. Results: Scanning electron micrographs showed a mean marginal microgap of 0.89 m (SD 1.67) for all assemblies. Significant differences (P < .001) were observed between mean ( SD) microgap measurements of the four tested systems: Ba = 0.38 0.28 m; Zd = 0.55 0.23 m; Nb = 1.83 3.21 m; Ca = 0.90 0.59 m. The mean microgap of the first 20 m of the outer region (1.66 m) was significantly (P < .001) larger than the mean microgap (0.56 m) of the inner region (30 to 100 m). Conclusions: Within the limitations of this study, the mean microgap observed for all tested systems was less than 2 m. For each system, the microgap decreased quickly from the outer region to the inner. The mean gap was larger for flat-to-flat connection systems, compared to internal-connection systems with a conical interface. These results demonstrate smaller microgaps compared to those described in the literature for titanium abutments. The precise fit of these abutments could lead to better biologic and biomechanical behavior. Int J Oral Maxillofac Implants 2010;25:455460


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help