LOGIN
 
Share Page:
Back

Volume 17 , Issue 3
May/June 2002

Pages 377–383


Histomorphometric Analysis of the Bone-Implant Contact Obtained with 4 Different Implant Surface Treatments Placed Side by Side in the Dog Mandible

Arthur B. Novaes, Jr, DDS, PhD, Sérgio L. S. Souza, DDS, PhD, Paulo T. de Oliveira, DDS, PhD, Adriana M. M. S. Souza, DDS, MSc


PMID: 12074453

Purpose: The different implant systems available today present several types of surface treatment, with the aim of optimization of bone-implant contact. This study compared 4 different types of implant surfaces. Materials and Methods: The first, second, third, and fourth mandibular premolars were extracted from 5 young adult mongrel male dogs. Ninety days after removal, four 3.75-mm-diameter, 10-mm-long screw-type implants (Paragon) were placed with different surface treatments in mandibular hemiarches. The dogs received 2 implants of each of the following surface treatments: smooth (machined), titanium plasma spray (TPS), hydroxyapatite coating (HA), and sandblasting with soluble particles (SBM). The implants were maintained unloaded for 90 days. After this period, the animals were sacrificed, and the hemimandibles were extracted and histologically processed to obtain nondecalcified sections. Two longitudinal ground sections were made for each implant and analyzed under light microscopy coupled to a computerized system for histomorphometry. Results: The following means were obtained for bone-implant contact percentage: machined = 41.7%, TPS = 48.9%, HA = 57.9%, and SBM = 68.5%. Discussion: The means for all treatments that added roughness to the implant surface were numerically superior to the mean found for the machined surface. However, this difference was statistically significant only between groups SBM and machined (Tukey test, P < .05). Conclusions: The SBM-treated surface provided a greater bone-implant contact than a machined surface after 90 days without loading in this model. (INT J ORAL MAXILLOFAC IMPLANTS 2002;17:377–383)


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help