Volume 24 , Issue 6
November/December 2009

Pages 10151032


Meta-analysis of Methods Used to Assess Implant Stability

Murat Cavit Cehreli, DDS, PhD/Durdu Karasoy, MSc, PhD/Kivanc Akca, DDS, PhD/Steven E. Eckert, DDS, MS


PMID: 20162105

Purpose: To evaluate correlations between Periotest, cutting torque or insertion torque, and/or the reverse torque test with resonance frequency analysis measurements. Materials and Methods: The combined search terms dental implant, primary stability, resonance frequency analysis, removal torque, vibration analysis, torque, Periotest, cutting torque, and insertion torque and specific inclusion and exclusion criteria were used to retrieve eligible articles published between 1998 and 2008 (up to April 1) from PubMed, EMBASE, OVID, The Cochrane Library databases, and 10 journals by hand-searching. The pooled P value was calculated with the Fisher method. The correlation coefficients (r) were combined using fixed and random effect models. Heterogeneity of the studies was tested by performing the homogeneity test. Results: Fifty articles were identified, but 3 studies were excluded because of limitations in study design. Studies that fulfilled the inclusion criteria fell into a variety of categories (11 human cadaver, 16 clinical, 15 animal, and 5 in vitro studies). Assessment of P values revealed that correlation between cutting torque or insertion torque and resonance frequency analysis was significant (6 studies; P = .0022). Correlation between Periotest and cutting torque or insertion torque was significant (1 study; P = .015), and correlations between resonance frequency analysis and reverse torque test values (1 study; P = .319; r = 0.405) and Periotest and resonance frequency analysis (P = .28) were insignificant. Nine articles provided r values, and cutting torque or insertion torque and resonance frequency analysis showed a statistically significant and direct relationship of 55.4% (P = .000). One study provided an r value of 0.149. A statistically significant and direct relationship of 87.6% was found between cutting torque or insertion torque and reverse torque (2 studies; P = .000). Conclusion: This meta-analysis of 47 studies showed a statistically significant correlation between cutting torque or insertion torque and resonance frequency analysis. Int J Oral Maxillofac Implants 2009;24:10151032


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help