LOGIN
 
Share Page:
Back

Volume 24 , Issue 5
September/October 2009

Pages 877866


Effects of Implant Diameter, Insertion Depth, and Loading Angle on Stress/Strain Fields in Implant/Jawbone Systems: Finite Element Analysis

Lihe Qian, PhD/Mitsugu Todo, PhD/Yasuyuki Matsushita, DDS/Kiyoshi Koyano, DDS


PMID: 19865628

Purpose: To investigate the interactions of implant diameter, insertion depth, and loading angle on stress/strain fields in a three-dimensional finite element implant/jawbone system and to determine the influence of the loading angle on stress/strain fields while varying the implant diameter and insertion depth. Materials and Methods: Four finite element models were created, which corresponded to two implant diameters and two insertion depths. The jawbone was composed of cortical and cancellous bone and modeled as a linearly elastic medium; the implant had a detailed screw structure and was modeled as an elastic-plastic medium. Static loading was applied to the coronal surface of the implant with a maximum load of 200 N for all the models. Loading directions were varied, with buccolingually applied loading angles ranging from 0 to 85 degrees. Results: Increases in the angle of force application caused not only increased maximum stress/strain values but worsened stress/strain distribution patterns in the bone and implant. The maximum stress in the bone always occurred at the upper edge of the cortical bone on the lingual side adjacent to the implant. The use of a larger-diameter implant or an increased insertion depth significantly reduced the maximum stress/strain values, improved the stress/strain distribution patterns and, in particular, decreased the stress/strain sensitivity to loading angle. Conclusions: A narrow-diameter implant, when inserted into jawbone with a shallow insertion depth and loaded with an oblique loading angle, is most unfavorable for stress distribution in both bone and implant. An optimized design of the neck region of an implant, in combination with a carefully controlled implant insertion depth that sets the threads of the implant neck well below the upper edge of the cortical bone, should be especially effective in improving the biomechanical environment for the maintenance of bone in implant/bone systems. Int J Oral Maxillofac Implants 2009;24:877866


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help