Comparison of Torque Measurements and Clinical Handling of Various Surgical Motors

Jorg Neugebauer /Martin Scheer /Robert A. Mischkowski /Sang-Ho An /Viktor E. Karapetian /Helge Toutenburg /Joachim E. Zoeller


PMID: 19587869

Purpose: Modern implant dentistry requires the application of torque during various treatment steps. This study investigated seven different surgical motors for the accuracy of the applied torque and their reliability. Materials and Methods: The following surgical motors were evaluated: Chiropro 980 (Bienair), INTRAsurg 300 and INTRAsurg 500 (KaVo), Osseocare (Nobel Biocare), Surgic XT (NSK), Elcomed SA-200 C (W&H), and Osseo System (XO Dentalcare). The torque was measured during typical surgical and prosthetic procedures using a special load transfer mechanism for a torque gauge. For each setting, 30 measurements were made and means were calculated. Results: The highest percentage shortfall was 20.5% at a set torque of 11.4 Ncm (absolute deviation of 2.4 Ncm). The highest percentage by which a torque was exceeded was 54.6% (absolute deviation of 5.5 Ncm). The lowest value for absolute shortfall was found to be 5.6 Ncm at a set torque of 45 Ncm. The highest absolute exceeded was 15 Ncm at a set torque of 40 Ncm. Potentially problematic torque values were identified in the low-torque-value setting, as the implant position may be changed if a machine driver applies excessive torque to the first-stage healing screw. In addition, in the indication of immediate loading in the high-set-torque group, torque values above the critical value of 50 Ncm may be unwittingly applied while working with a set torque of 40 Ncm. Conclusion: For most of the clinically relevant torque settings, precise values were measured, although a few devices delivered potentially problematic torque values for some of the indications. Int J Oral Maxillofac Implants 2009;24:469476


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help