LOGIN
 
Share Page:
Back

Volume 24 , Issue 3
May/June 2009

Pages 455462


Biomechanical Effects of a Maxillary Implant in the Augmented Sinus: A Three-Dimensional Finite Element Analysis

Heng-Li Huang /Lih-Jyh Fuh /Ching-Chang Ko /Jui-Ting Hsu /Chern-Chin Chen


PMID: 19587867

Purpose: The biomechanical effects of different strengths of grafted bone, bicortical anchorage, and dimensional alterations of a dental implant with maxillary sinus augmentation were investigated. Materials and Methods: Sixteen finite element (FE) models that included five implant lengths, two implant diameters, and grafted bone with two levels of stiffness were studied. A posterior maxillary model was constructed from computerized tomographic images of a human skull, and the implant models were created via computer-aided design software (SolidWorks 2006). All materials were assumed to be isotropic and linearly elastic. A 45-degree oblique force of 129 N was applied to the buccal cusp of the first molar. Results: The von Mises stress was highest in the 7-mm-long implant. Stresses in cortical and trabecular bone were reduced by at least 50% for all other implants (length≥ 8.5 mm) with bicortical anchorage. Increasing the length of the bicortically anchored implant did not decrease the stress in native bone, but it decreased the stress in sinus grafts by at least 20%. The use of a wide implant decreased the stress by 24% to 42% in cortical bone and 17% to 36% in trabecular bone. Increasing the elastic modulus of grafted bone decreased the stress in native bone by approximately 10%. Conclusions: Bicortical fixation of implants and the presence of grafted bone with greater stiffness reduced the stresses in native bone. Increasing the length of the implant in grafted bone did not reduce the stress in native bone, but it did reduce the stress in grafted bone. The effects of implant diameters on reducing bone stress are primarily a result of the increased contact area between implant and bone. The results of the FE analysis imply that the success of a sinus-augmented dental implant is heavily dependent on the implant design and rigidity of the bone grafts. Int J Oral Maxillofac Implants 2009;24:455462


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help