LOGIN
 
Share Page:
Back

Volume 5 , Issue 4
Winter 1990

Pages 405-408


Converting an Implant-Supported Fixed Prosthesis to an Overdenture Because of Fixture Loss: A Case Report

Tze-Cheung Yeung, BDS/Lee M. Jameson, DDS, MS


PMID: 2094660

A patient with a failed implant-supported prosthesis was treated with an immediate interim overdenture. After insertion of a bar modified from the prosthesis substructure, the patient was restored with an implant supported overdenture. A bar soft liner retention system was used to aid retention and stability of the overdenture. (INT J ORAL MAXILLOFAC IMPLANTS 1990;5:405-408.)

Key words: Brånemark implant, interim overdenture, overdenture, soft liner


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home