Forces and Moments on Brånemark Implants
Bo Rangert, Mech Eng, PhD/Torsten Jemt, DDS, PhD/Lars jörneus, Mech Eng, MSc
PMID: 2700747
The placement of fixtures (implants) in relation to the geometry of a prosthetic restoration has a great influence on the mechanical loading of the implant. Based on theoretic consideration and clinical experiences with the Brånemark System, this article gives simple guidelines for controlling these loads. The emphasis is on design rules that can be used in clinical practice. With the Class I lever as a reference, various clinical implant prosthesis situations are discussed and evaluated. (INT J ORAL MAXILLOFAC IMPLANTS 1989;4:241-247.)
Key words: Brånemark implant, cantilever, fixture position, force, load, moment