LOGIN
 
Share Page:
Back

Volume 15 , Issue 1
January/February 2000

Pages 111118


Measurement of Misfit at the Implant-Prosthesis Interface: An Experimental Method Using a Coordinate Measuring Machine

Conor Mulcahy, BA, BDent Sci, MSc, Martyn Sherriff, BSc, PhD, MIM, FSS, John D. Walter, BDS, DDS, FDSRCS (Ed), Michael R. Fenlon, PhD, MA, BDent Sci, FDSRCS (Ed), MGDS (Ed)


PMID: 10697945

Measurement of misfit at the implant-prosthesis interface is a difficult procedure. One factor common to all methods that attempt to measure 3-dimensional distortion to the micron level is the difficulty in providing verifiably consistent reference points between individual measurement sets. Consequently, the majority of studies use a relative distortion model in which the coordinate reference system is integral to the framework, thus limiting the value of the data gathered. In the method described, the datum plane and the coordinate reference system were set up external to the framework and could be re-established between measurement sets in a verifiable manner. (INT J ORAL MAXILLOFAC IMPLANTS 2000;15:111118) Key words: coordinate measuring machine, datum plane, framework, implant


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help