Abutment Screw Loosening in Single-Implant Restorations: A Systematic Review

Anna Theoharidou, DDS/Haralampos P. Petridis, DDS, PhD, MSc/Konstantinos Tzannas/Pavlos Garefis, DDS, PhD


PMID: 18807565

Purpose: The purpose of this study was to systematically review clinical studies on the incidence of abutment screw loosening in single-implant restorations with different implant-abutment connection geometries. Materials and Methods: The literature search was conducted using several electronic databases. Specific terms were used for the database search, which spanned the years 1990 to 2006. The search was augmented by using the option of “related articles” as well as hand searching of references and relevant journals. Relevant studies were selected according to predetermined inclusion and exclusion criteria. Agreement between reviewers was determined by using Cohen’s kappa coefficients. Three-year complication-free rates (survival proportions) were calculated with the aid of a survival function, assuming constant failure rates. Summary estimates per group for complication-free rate after 3 years (M-estimator) were calculated using Tukey’s biweight estimator. Results: The initial database search yielded 1,526 relevant titles. After the subsequent filtering process, 27 studies were finally selected. Interexaminer agreement ranged from good to perfect. The external-connection group comprised 12 studies following 586 single-implant restorations for a mean follow-up time that ranged from 3 to 5 years. The estimated percent of complication-free single-implant restorations after 3 years was 97.3% (95% CI: 95.6–98.3). The internal connection group comprised 15 studies following 1,113 single-implant restorations for a mean follow-up time that ranged from 3 to 10 years. The estimated percentage of complication-free single-implant restorations after 3 years was 97.6% (95% CI: 96.5–98.3). Conclusion: The results show that abutment screw loosening is a rare event in single-implant restorations regardless of the geometry of implant-abutment connection, provided that proper antirotational features and torque are employed. Int J Oral Maxillofac Implants 2008;23:681–690

Key words: implant complications, implant geometry, meta-analysis, screw loosening, single implants


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help