Strain Development in 3-unit Implant-Supported CAD/CAM Restorations

Matthias Karl, DMD/Manfred G. Wichmann, DMD/Siegfried M. Heckmann, DMD/Tim Krafft, DMD, MD


PMID: 18807560

Purpose: Passive fit is difficult to achieve in implant-supported restorations with existing superstructure fabrication techniques. The aim of the study presented was to investigate whether computer-generated fixed partial dentures (FPDs) based on optical impressions lead to less strain development than conventionally fabricated FPDs. Materials and Methods: A measurement model with 2 implants was set up and strain gauges were attached to the model material mesially and distally adjacent to the implants. Two groups of conventional cementable restorations based on repositioning and pick-up impressions, respectively, and 1 group of CAD/CAM-generated FPDs based on optical impressions were fabricated (n = 10). Strain development during FPD fixation was recorded. In order to compare the different FPD groups with one another, a multivariate analysis of variance (MANOVA) was performed at a level of significance of a = .05. Results: The mean strain development at the different strain gauge locations ranged from 80.38 m/m to 437.11 m/m. The 2 groups of conventionally fabricated FPDs showed no significant difference in terms of strain development (P = .07). The CAD/CAM-fabricated FPDs revealed a significantly lower strain development than those made from pick-up technique impressions (P = .01). No significant difference could be detected between the FPDs manufactured from repositioning technique impressions and the CAD/CAM-generated restorations (P = .19). Conclusion: Within the limitations of the study presented, it can be concluded that restorations fabricated on the basis of optical impressions demonstrate a level of fit which is at least as passive as that of conventional FPDs. Int J Oral Maxillofac Implant 2008;23:648652

Key words: CAD/CAM, implant-supported restoration, impression accuracy, passive fit


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help