Strength of CAD/CAM-Generated Esthetic Ceramic Molar Implant Crowns

Daniel Wolf, Dr Med Dent/Andreas Bindl, PD Dr Med Dent/Patrick R. Schmidlin, PD Dr Med Dent/Heinz Lüthy, Prof Dr/Werner H. Mörmann, Prof Dr Med Dent


PMID: 18807555

Purpose: One-visit in-office CAD/CAM fabrication of esthetic ceramic crowns as a superstructure for posterior implants is quite new. The aim of the study was to evaluate the strength of esthetic ceramic CAD/CAM crowns with varied occlusal thickness and seated with adhesive and nonadhesive cements on titanium and zirconia abutments. Materials and Methods: Esthetic ceramic CAD/CAM-generated molar crowns (n = 15 per group) with occlusal thicknesses of 0.5 mm and 1.5 mm were seated on titanium (1) and zirconia (2) abutments: noncemented (a) and with nonadhesive cement (b) or 2 adhesive resin-based cements (c) and (d). In addition, 15 molar crowns with 5.5-mm occlusal thickness were seated on short zirconia abutments (3) using cements (c) and (d). All crowns had the identical occlusal morphology and were loaded with a crosshead speed of 0.5 mm/min until fracture. Load data were analyzed using 2-way ANOVA, the Scheffé test, and Weibull probability of failure analysis. Results: Fracture loads of 1.5-mm occlusal thickness crowns (a, b, c, d) were higher (P < .001) than those of 0.5-mm crowns (except for group 1d). Occlusal 5.5-mm crowns on short zirconia abutments had similar (2c) or less (2d) strength than the respective 1.5-mm crowns. Nonadhesive crowns (1b, 2b) were weaker (P < .001) than adhesive crowns (1c, 1d, 2c, 2d). Fracture loads of 0.5- and 1.5-mm crowns were significantly higher on titanium than on zirconia abutments with both cements. Adhesive cement d generally showed higher fracture loads than c on both titanium and zirconia. Conclusion: Esthetic ceramic CAD/CAM molar implant crowns gained high strength with adhesive cements on both titanium and zirconia implant abutments compared to nonadhesive cementation. Int J Oral Maxillofac Implants 2008;23:609–617

Key words: adhesive cementation, CAD/CAM esthetic ceramic, CAD/CAM implant crowns, fracture load, titanium abutments, zirconia abutments


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help