Volume 23 , Issue 2
March/April 2008

Pages 315–322


Immediate Occlusal Loading of Implants in the Partially Edentate Mandible: A Prospective 1-Year Radiographic and 4-Year Clinical Study

Pär-Olov Östman, DDS, PhD/Mats Hellman, DDS/Lars Sennerby, DDS, PhD


PMID: 18548929

Purpose: The purpose of the present prospective clinical study was to evaluate the radiographic and clinical outcome of immediately loaded implants in the partial edentulous mandible over a 4-year follow-up period using a modified surgical protocol, primary implant stability criteria, and splinting for inclusion. Materials and Methods: Patients in need of implant treatment in the partial edentate mandible were consecutively included in the study. The implant sites were underprepared to obtain maximal stability. Inclusion criteria for the study were torque of a least 30 Ncm before final seating of the implant and an ISQ greater than 60. A provisional fixed partial denture was delivered within 24 hours and a definitive fixed partial denture within 3 months. The patients were monitored with clinical and radiographic follow-up examinations for up to 4 years. Stability of the implants was measured with resonance frequency analysis at placement and after 6 months. Results: Ninety-six patients were evaluated, and 77 patients who met the inclusion criteria were included. A total of 111 fixed partial dentures supported by 257 Brånemark System implants (77 turned and 180 TiUnite implants) were delivered. Four (1.6%) of the 257 implants did not osseointegrate, giving an overall survival rate of 98.4% after 4 years. Three turned (3.9%) implants and 1 oxidized implant (0.6%) failed after 4 to 13 months. The average marginal bone resorption was 0.7 mm (SD 0.78) during the first year in function. Turned implants showed an average bone loss of 0.5 mm (SD 0.8) and oxidized implants an average of 0.7 mm (SD 0.8). Resonance frequency analysis showed a mean implant stability quotient of 72.2 (SD 7.5) at placement and 72.5 (SD 5.7) after 6 months of loading. Conclusion: It is concluded that immediate loading of implants with firm primary stability in partially edentulous areas of the mandible appears to be a viable procedure with predictable outcome. (Comparative Cohort Study) Int J Oral Maxillofac Implants 2008;23:315–322

Key words: dental implants, immediate loading, insertion torque, partially edentulous mandible, primary stability, prospective study, resonance frequency analysis


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2014 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help